In this guide: 1. Oxygen demand · 2. Standard conditions · 3. Airflow · 4. Number of diffusers · 5. Blower · Disc or tube
Aeration consumes between half and two thirds of the energy of an activated sludge plant. That is why sizing diffusers correctly is not a detail: an undersized system cannot reach the required dissolved oxygen, and an oversized one wastes blower energy over the entire life of the plant. This is the method, in five steps.
1. Calculate the actual oxygen requirement (AOR)
The actual oxygen requirement (AOR) is the oxygen the biomass consumes under process conditions. It depends on the organic load removed (BOD or COD) and, if there is nitrification, on the ammonia nitrogen oxidized: each kilogram of NH₄-N nitrified requires about 4.57 kg of O₂. It is expressed in kg O₂/day and must be calculated for the peak load, not just the average.
2. Convert to standard conditions (SOR)
Manufacturers report diffuser performance in clean water, at 20 °C and at sea level. To compare, the AOR is converted into the standard oxygen requirement (SOR) by correcting for:
- Alpha factor (α): how much the wastewater reduces transfer compared with clean water. For fine bubble it is noticeably lower than 1, and drops further with grease and surfactants.
- Liquid temperature.
- Plant altitude: the higher the site, the lower the atmospheric pressure and oxygen saturation.
- Operating dissolved oxygen: usually 2 mg/L in the reactor.
For fine bubble, the SOR usually ends up at twice the AOR, or somewhat more.
3. Calculate the airflow
With the SOR and the diffuser transfer efficiency, the airflow is obtained:
Airflow (Nm³/h) = SOR (g O₂/h) ÷ (SSOTE × submergence)
Where SSOTE is the specific oxygen transfer of the diffuser (g O₂ per Nm³ of air and per meter of submergence) and submergence is the diffuser depth in meters. Our fine bubble disc and tube diffusers reach up to 25 g O₂/Nm³·m. That is why deep tanks pay off: each additional meter of submergence increases the oxygen transferred per cubic meter of air.
Example. A plant with an SOR of 1,000 kg O₂/day (41.7 kg/h) and diffusers at 4.3 m submergence. At 25 g O₂/Nm³·m, each Nm³ of air transfers 107.5 g of O₂. The required airflow is 41,700 ÷ 107.5 = 388 Nm³/h.
4. Define the number and layout of diffusers
The total airflow is divided by the design airflow per diffuser. Each model has a recommended range: below it, air distribution becomes uneven; above it, bubbles grow and efficiency drops. Working in the lower part of the range improves transfer and reduces head loss, at the cost of more diffusers.
Two final checks:
- Minimum mixing: the airflow must keep solids in suspension even at low load. If oxygen demand is low and the tank is large, mixing rather than oxygen may set the airflow. In that case, consider submersible mixers.
- Layout: the grid must cover the floor evenly, with no dead zones, and the diffusers must be level so they all receive the same airflow.
5. Select the blower
The blower discharge pressure is the sum of the submergence, the diffuser head loss and the piping losses, plus a margin. The airflow is corrected for altitude and inlet temperature, because the blower moves volume and air at altitude is less dense. For medium flows, rotary lobe blowers reach 360 m³/min and 315 kW. For large plants with variable demand, turbo blowers offer higher energy efficiency.
Disc or tube
Discs are preferred in flat-bottom tanks with a full-floor grid and aim for maximum efficiency per diffuser. Tubes install more membrane area per connection, which lowers installation cost in large tanks. Both are built with a reinforced polypropylene body and an EPDM, silicone or polyurethane membrane, for 2″ to 6″ pipework.
Want us to size your system? Send us the flow, the load and the tank depth and we will put together a proposal with TORVON® diffusers and the right blower.